Tekoa SoftwareTEKOA

software  

 Tekoa Software Home Page

Home

|

 Tekoa Software News

News

|

Tekoa Software Support

Support

|

 Tekoa Software Login

Sign In

Tekoa Software Home 

Tekoa Software Development and Dedicated Server Hosting. 

 

Customer Service 

Contact Customer Service if you need more help. 

 

Sage MAS 90 200 Application Host 

Secure Application Hosting for Sage MAS 90 200 for todays enterprise. Get more from the software you already own. 

 

 
Sage MAS 200 Cloud Computing

Web Services, Tekoa MAS Web Browser, Customer Portal, Essential Technical Support...

All part of Tekoa's Cloud Computing Solution for MAS90 and MAS200.  Technology for today's web enabled enterprise.

MAS 90 200 Support
MAS 90 200 Paperless Office Email that Works!
 More Information...

Tekoa Software Knowledgebase Tekoa Software Knowledgebase 

Find answers to your technical support questions using our knowledgebase.

Using the seach below, enter keywords related to your technical support question. We will search our support database and find support articles related to your inquiry.


 
 
Title

Moving MAS 90 or MAS 200 to a new location 

ID 0000000022 
Subtitle Moving MAS 90 or MAS 200 
Description How to move MAS 90/200 to a new server, hard drive or directory 
Text Always take a complete backup of the old MAS location before proceeding.

If eBusiness Manager is used, also change the path of the application server in... \Webeng\\Home\Lib\_web\Webhide.ini on the Web Engine server. 
 
Resolution For MAS 90 4.0 or higher:
1. Copy (DO NOT MOVE) the entire contents of the ..\Mas90\ directory to the new location. Moving the directory itself is not recommended because should there be any interruption in the process, data can be damaged or lost.

2. In the new location, using Windows Explorer, rename the ..\Uninstall Information folder.

3. Reinstall 'System Setup' and 'Library Master' and the same original modules at the server so that a new installation is recorded by InstallShield. Note that if security was enabled during the original installation of MAS 90, it must be enabled at the new server as well. Any third-party enhancements must also be reinstalled.

4. Create new mappings on all workstations.

5. Re-run workstation setup at all workstations. Replace any shortcut icons that point to the original location. If the new server has the same name and patch as the original server, this step does not need to be done.

6. Start MAS 90 from the new location to verify that the program and the company data is still accessible and that no errors occur.

7. To verify that the new location of MAS 90 is running properly, go to the File menu, select Run and enter '*INFO'. Verify the path. After the copy of MAS 90 is complete, the original directory can be deleted.

For MAS 200 4.0 or higher:
NOTE: The Application Server Service registry keys may still point to the original location. If you move the MAS 200 v 4.xx to a new location on the same server, then the Application Server Service must first be removed (only after completing a full backup!), then reinstalling the Mas 200.

1. Copy (DO NOT MOVE) the entire contents of the ..\Mas90\ directory to the new location. Moving the directory itself is not recommended because should there be any interruption in the process, data can be damaged or lost.

2. The the new location, delete the ..\MAS90\Uninstall Information directory and the ..\MAS90\home\lib\_appserv directory.

3. Reinstall System Setup and Library Master and the same original modules at the new location so that a new installation will be recorded by InstallShield. This also installs the Application Server components in the new location. Re-enter registration information as requested. If security was enabled during the original installation of MAS90, it must be enabled at the new location with the same administrator password. You will need to re-enter registration keys. They can be obtained by logging into 'Sage Software Online', then by clicking 'Profile Management', 'Products', 'View Sage MAS90/200 Product Key' and 'Validate'.

4. In Application server Configuration, assign an unused port to the server and click Start or set up as a service. If running as a service, DO NOT run the service on the system account, as login must be done by the Local Administrator, Domain User.

5. Re-run workstation setup at all workstations and replace shortcut icons that point to the original MAS 200 location.

6. Start MAS 90 from the new location to verify that the program and the company data is still accessible and that no errors occur.

7. To verify that the new location of MAS 90 is running properly, go to the File menu, select 'Run' and enter '*INFO'. Verify the path. After the copy of MAS 90 is complete, the original directory can be deleted.

For MAS 90 ver 3.71 or earlier:
1. Copy (DO NOT MOVE) the entire contents of the ..\Mas90\ directory to the new location. Moving the directory itself is not recommended because should there be any interruption in the process, data can be damaged or lost.

2. Re-run workstation setup at all workstations. Replace any shortcut icons that point to the original location. If the new server has the same name and patch as the original server, this step does not need to be done.

3. Start MAS 90 from the new location to verify that the program and the company data is accessible and that there are no errors. After the copy of MAS 90 is complete, the original directory can be deleted.

For MAS 200 ver 3.71 or earlier:
1. Copy (DO NOT MOVE) the entire ..\Mas90\ directory to the new location.

2. Reinstall System Setup at the server to install the HOST components.

3. Rerun workstation setup at all workstations and replace any shortcut icons that point to the original location. If the new server has the same name, TCP/IP address, and the path as the original server, rerunning workstation setup is NOT required.

4. Start MAS 90 from the new location to verify that the program and the company data is accessible and no errors occur.

5. After the copy has been verified as successful, the original ..\MAS90\ directory can be deleted.







 
Related Link 1 http://www.tekoasoftware.com/ 
Related Link 2  
 Sage MAS Knowledgebase Search
Clear

Sage MAS 90 MAS 200 Knowledgebase Articles 
Kb Title Kb ID Category Type
Barcode Printing Crystal Reports Sage MAS 90 200 

0000000003 

Sage MAS 90 200 Technical Support  Technical Support 
Downloading, Installing and Updating Tax Tables 

0000000031 

Sage MAS 90 200 Technical Support  How To Instructions 
What if I forget my password? 

0000000002 

Frequently Asked Questions  General Information 
Printer using ports not COM, LPT or USB 

0000000059 

Sage MAS 90 200 Technical Support  Technical Support 
PVXWIN32.EXE - DLL Initialization Failed 

0000000013 

Sage MAS 90 200 Technical Support  Technical Support 
MAS 90 200 Q1 2009 Tax Table Update 

0000000039 

Frequently Asked Questions  How To Instructions 
How To Use Item Alias Codes in MAS 90 200 

0000000010 

Sage MAS 90 200 Technical Support  How To Instructions 
MAS 90 200 Paperless Office Email Errors 

0000000044 

Sage MAS 90 200 Technical Support  Technical Support 
Can I Export MAS 90 200 Reports to Excel or Word? 

0000000011 

Frequently Asked Questions  How To Instructions 
Reversing a Credit Card Payment in MAS 90 or 200 

0000000026 

Sage MAS 90 200 Technical Support  Technical Support 
Rebuilding key files in MAS 90 and MAS 200 

0000000032 

Sage MAS 90 200 Technical Support  Technical Support 
Invoice Already Being Paid of Balance Exceeded 

0000000034 

Sage MAS 90 200 Technical Support  Technical Support 
Error 11 POWUZA 3330 when Rebuilding Sort Files 

0000000006 

Sage MAS 90 200 Technical Support  Technical Support 
Error 11 POSUZA 3330 

0000000020 

Sage MAS 90 200 Technical Support  Technical Support 
Crystal Reports Export To Text Do Not Prompt 

0000000025 

Sage MAS 90 200 Technical Support  How To Instructions 
Moving MAS 90 or MAS 200 to a new location 

0000000022 

Sage MAS 90 200 Technical Support  Technical Support 
Runtime DLL Files for Special Formulas 

0000000023 

Sage MAS 90 200 Technical Support  General Information 
How to register .DLL and .OCX files 

0000000057 

Sage MAS 90 200 Technical Support  How To Instructions 
Creating a one-sided journal entry 

0000000028 

Sage MAS 90 200 Technical Support  Technical Support 
Installing Workstation Setup for MAS 90 & 200 

0000000027 

Sage MAS 90 200 Technical Support  Technical Support 
TCP/IP Connection Failure in MAS 200 

0000000014 

Network Support  Technical Support 
MAS 90 MAS 200 2009 Payroll 941 Program Update 

0000000045 

Sage MAS 90 200 Technical Support  Technical Support 
Setting Default Printers in MAS 90 & 200 

0000000040 

Sage MAS 90 200 Technical Support  Technical Support 
Setting a Default Device Configurator Printer 

0000000046 

Sage MAS 90 200 Technical Support  How To Instructions 
Microsoft IIS Loses MAS 90 200 ODBC Connection. 

0000000041 

Sage MAS 90 200 Technical Support  Technical Support 
How to Back Up and Restore Data Files 

0000000030 

Sage MAS 90 200 Technical Support  Technical Support 
"A goods receipt is currently referencing this PO" 

0000000055 

Sage MAS 90 200 Technical Support  Technical Support 
A goods receipt is currently referencing this PO 

0000000015 

Sage MAS 90 200 Technical Support  Technical Support 
Error 88 SY_ReportEngine.pvc 1127  

0000000051 

Sage MAS 90 200 Technical Support  Technical Support 
Error 88 SY_ReportEngine.pvc 1535 when printing 

0000000052 

Sage MAS 90 200 Technical Support  Technical Support 
Add the ability to edit/revise menus in MAS90/200 

0000000019 

Sage MAS 90 200 Technical Support  General Information 
Installing Service Packs, Updates or Program fixes 

0000000029 

Sage MAS 90 200 Technical Support  Technical Support 
Displaying Data File Records with the DFDM Utility 

0000000035 

Sage MAS 90 200 Technical Support  Technical Support 
Modifying Records using the DFDM Utility 

0000000036 

Sage MAS 90 200 Technical Support  Technical Support 
Deleting Records Using the DFDM Utility 

0000000037 

Sage MAS 90 200 Technical Support  Technical Support 
Sage MAS 90 200 Payroll Tips on W-2 Are Incorrect 

0000000005 

Sage MAS 90 200 Technical Support  Technical Support 
Error: "(CheckOFSIConnection) 8900: 

0000000042 

Sage MAS 90 200 Technical Support  Technical Support 
Finance Charges Not Calculated  

0000000024 

Sage MAS 90 200 Technical Support  Technical Support 
Reports Default to Wrong Printer in Crystal Report 

0000000047 

Sage MAS 90 200 Technical Support  Technical Support 
The object SO_SalesOrder_UI does not exist 

0000000017 

Sage MAS 90 200 Technical Support  Technical Support 
Install or Uninstall PDF Converter 

0000000058 

Sage MAS 90 200 Technical Support  How To Instructions 
Object ProvideX.Script was invalid 

0000000021 

Sage MAS 90 200 Technical Support  Technical Support 
Connection failure to host 

0000000012 

Network Support  Technical Support 
Financial Reports Defaulting to Incorrect Printer 

0000000048 

Sage MAS 90 200 Technical Support  Technical Support 
Error 13 SO_PurgeSalesHistory.pvc Line 140 

0000000004 

Sage MAS 90 200 Technical Support  Technical Support 
Error 65 CI_Audit Tracking.pvc 132 

0000000016 

Sage MAS 90 200 Technical Support  Technical Support 
Error 71 SO_SALESORDER_UI.PVC 515 

0000000018 

Sage MAS 90 200 Technical Support  Technical Support 
"Data is not selected for report printing" in RMA  

0000000049 

Sage MAS 90 200 Technical Support  Technical Support 
Default RMA date is retained in RMA Entry  

0000000053 

Sage MAS 90 200 Technical Support  Technical Support 
Credit Memos Posting to Incorrect Warehouse 

0000000038 

Sage MAS 90 200 Technical Support  Technical Support 
Error 88 Sy_ReportEngine.pvc 702 when printing  

0000000050 

Sage MAS 90 200 Technical Support  Technical Support 
Error 12 SY_PDF Converter.pvc 369 

0000000056 

Sage MAS 90 200 Technical Support  Technical Support 
Residential address check box is cleared on SO's 

0000000054 

Sage MAS 90 200 Technical Support  Technical Support 
Cannot connect to database for pages w/ MAS data 

0000000007 

Tekoa ERP Software Support  Technical Support 
FireBox VPN instability from remote office to Host 

0000000008 

Network Support  Technical Support 
Grids with multiple tables pass blank variables. 

0000000009 

Tekoa ERP Software Support  Technical Support 
FRX: Run-Time Error -2147220503 

0000000043 

All Categories  Technical Support 

 Tekoa Software, Inc.  All Rights Reserved. General: 509-340-3580       Support: 509-340-3733     Contact Us

www.TekoaSoftware.com 

 software for today's web enabled enterprise  Web Software Development  |  Web Design  |  eBusiness Solutions  | Web Enterprise  |  Business Management Software

  Tekoa Software Blog